Certs in Order

How to read an EICR

An EICR (Electrical Installation Condition Report) is what an electrician writes after inspecting and testing the fixed wiring. Read three things: the codes against each observation, whether the report says the installation is unsatisfactory, and the date given for the next inspection. If any observation is coded C1 or C2, remedial work is required.

The four codes

The inspector gives each problem found a code. The wording below is from the GOV.UK guidance on electrical safety standards in rented homes.

EICR classification codes, from GOV.UK guidance read on 26 November 2026
CodeWhat GOV.UK says it meansWhat follows
C1Danger present. Risk of injury.Remedial work is required. The inspector may make a C1 hazard safe before leaving.
C2Potentially dangerous.Remedial work is required.
FIFurther investigation required without delay.For an inspection completed before 30 November 2026, the landlord must make sure the investigation is carried out within 28 days. For later inspections the amended regulations no longer require it, but Electrical Safety First says it should still be investigated as soon as possible.
C3Improvement recommended.No further work is needed for the report to be satisfactory.

The guidance says that when C1 or C2 codes are present, the report will state that the installation is unsatisfactory for continued use. Electrical Safety First’s Best Practice Guide 4 (issue 7.4) says the overall result must be recorded as unsatisfactory if any observation is coded C1 or C2. It doesn’t say an FI code on its own makes a report unsatisfactory. It describes FI as further investigation advised, for a possible problem the inspector couldn’t code without investigating further, and says it should be investigated as soon as possible. A report with only C3 codes can still be satisfactory.

A made-up example

This is not a real report, property or electrician, and it doesn’t copy any scheme’s form. Real reports run to several pages. These are the lines I’d read first.

Electrical Installation Condition Report (example only)

Made up for this guide. Flat 2, 14 Example Street, Birmingham.

Address
Flat 2, 14 Example Street, BirminghamMatches the tenancy agreement.
Date of inspection
9 June 2023
Observations
One C2, two C3A C2 means remedial work was required. Where is the written confirmation that it was done?
Overall result
UnsatisfactoryThis report alone doesn’t show the property is in order.
Next inspection by
9 June 2028Not yet passed.
Inspector
Name, signature and scheme detailsPresent.

In words: the example report is within its five years, but it found a C2 fault and says unsatisfactory. To go with it, the landlord needs the electrician’s written confirmation that the work was done.

The rules behind the report

These come from the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 and the GOV.UK guidance on them.

  • How often. The wiring must be inspected and tested by a qualified person at least every 5 years. If the latest report gives an earlier date for the next inspection, that earlier date applies.
  • What the report gives you. The results, and the date by which the next inspection is required.
  • If work is needed. Remedial work must be done by a qualified person within 28 days of the inspection, or sooner if the report says so. The landlord must then get written confirmation that it was done. For an inspection completed before 30 November 2026, the same applies to any further investigation the report says is needed. An amendment in force from 30 November 2026 removes that requirement for later inspections.
  • Copies. A copy goes to each existing tenant within 28 days of the inspection, to a new tenant before they move in, and to the local council within 7 days if it asks.
  • New builds and full rewires. These should have an Electrical Installation Certificate (EIC). The guidance says a landlord with an EIC doesn’t need a further report for 5 years after it was issued.

Some tenancies are excluded, such as accommodation shared with the landlord or the landlord’s family. The GOV.UK electrical safety guidance has the list.

legislation.gov.uk lists amendments made in 2026 that it hasn’t yet applied to the text of regulation 3. I’ve relied on the GOV.UK guidance for the current position. Check it before you rely on a time limit.

Checking the electrician

The regulations ask for a “qualified person”, meaning someone competent to do the inspection and testing. The GOV.UK guidance points landlords to the Registered Competent Person Electrical register to find a registered electrician.

What I’ll look for on an EICR

  • A next inspection date that has passed, or an inspection more than 5 years ago
  • A date that will pass before your region’s registration window closes
  • An unsatisfactory result, or any C1, C2 or FI code, with no written confirmation of the work alongside
  • An address that differs from the tenancy agreement or the other certificates
  • A document that isn’t an EICR or an EIC at all, such as a quote or an invoice
  • An EIC being relied on more than 5 years after it was issued

I can tell you what a report says and whether its dates have passed. I can’t tell you whether the wiring is safe. That is the electrician’s job.

What the landlord register asks for

The draft regulations ask for a copy of the EICR, if one exists, or the appropriate EIC, with the EICR’s expiry date or the EIC’s issue date. An EICR has no expiry date of its own, so for that field I’d use the date the report gives for the next inspection. See which certificates the register asks for. The other two documents have their own guides: how to read a gas safety record and how to read an EPC. The free calculator shows when your region’s window closes.

Sources

Each of these was read on 26 November 2026. If one of them changes, I’ll change this page and note it in the change log.

This page is general information, not legal advice. I’m not a solicitor, gas engineer, electrician or energy assessor. If you’re not sure a certificate is valid, ask the registered engineer or assessor who issued it.